Summary:Core Standards and Applicable Scenarios Class C fire door:
the fire resistance limit is ≥0.5h, and it is used for the inspection door of vertical sha......
Core Standards and Applicable Scenarios Class C fire door:
the fire resistance limit is ≥0.5h, and it is used for the inspection door of vertical shaft such as cable shaft, pipeline shaft and smoke exhaust duct on ordinary floors. Class B fire door: the fire resistance limit is ≥1.0h, which is mandatory when the access door opens to the floor to expand the front room, close the stairwell, the front room of the smoke-proof stairwell or some special areas with a building height greater than 100m. Class-A fire door: the fire resistance limit is ≥1.5h, which is rarely used for ordinary access doors, and only found in special mezzanine or extremely high fire separation requirements.